RESEARCH

Papers and sources.

Every number on this site traces back to something you can read: the literature that established fast optical signal, the sources behind our modality comparison, and a register of the claims we make and where each one stands.

Foundational fast optical signal papers

The method is variously called the fast optical signal (FOS), the event-related optical signal (EROS), or simply the fast signal, in contrast to the slow hemodynamic signal measured by the same instruments. These are the papers we hand to new hires, in roughly the order we hand them over.

  1. Shades of gray matter: noninvasive optical images of human brain responses during visual stimulation.
    Gratton, G., Corballis, P. M., Cho, E., Fabiani, M., & Hood, D. C. (1995).
    Psychophysiology, 32(5), 505–509.The first non-invasive demonstration in humans.
  2. Fast and localized event-related optical signals (EROS) in the human occipital cortex: comparisons with the visual evoked potential and fMRI.
    Gratton, G., Fabiani, M., Corballis, P. M., Hood, D. C., Goodman-Wood, M. R., Hirsch, J., Kim, K., Friedman, D., & Gratton, E. (1997).
    NeuroImage, 6(3), 168–180. doi:10.1006/nimg.1997.0298Places the optical response against EEG and fMRI in the same subjects.
  3. The event-related optical signal: a new tool for studying brain function.
    Gratton, G., & Fabiani, M. (2001).
    International Journal of Psychophysiology, 42(2), 109–121. doi:10.1016/S0167-8760(01)00161-1The clearest early statement of the method and its mechanism.
  4. Functional frequency-domain near-infrared spectroscopy detects fast neuronal signal in the motor cortex.
    Wolf, M., Wolf, U., Choi, J. H., Gupta, R., Safonova, L. P., Paunescu, L. A., Michalos, A., & Gratton, E. (2002).
    NeuroImage, 17(4), 1868–1875.Fast signal in motor cortex, on a frequency-domain instrument.
  5. The fast optical signal — robust or elusive when non-invasively measured in the human adult?
    Steinbrink, J., Kempf, F. C. D., Villringer, A., & Obrig, H. (2005).
    NeuroImage, 26(4), 996–1008.The skeptical paper. Read it; it frames the signal-to-noise problem we work on.
  6. Fast optical imaging of human brain function.
    Gratton, G., & Fabiani, M. (2010).
    Frontiers in Human Neuroscience, 4, 52. doi:10.3389/fnhum.2010.00052The review. Sub-centimeter localization, temporal resolution under 100 ms, penetration limited to about 3 cm.

Mechanism and physics

  1. Changes in neuron structure during action potential propagation and synaptic transmission.
    Cohen, L. B. (1973).
    Physiological Reviews, 53(2), 373–418.Why firing neurons change their optical properties at all.
  2. Noninvasive detection of changes in membrane potential in cultured neurons by light scattering.
    Stepnoski, R. A., LaPorta, A., Raccuia-Behling, F., Blonder, G. E., Slusher, R. E., & Kleinfeld, D. (1991).
    Proceedings of the National Academy of Sciences, 88(21), 9382–9386.
  3. Measurements of scattering and absorption changes in muscle and brain.
    Gratton, E., Fantini, S., Franceschini, M. A., Gratton, G., & Fabiani, M. (1997).
    Philosophical Transactions of the Royal Society B, 352(1354), 727–735.
  4. Frequency-domain techniques for cerebral and functional near-infrared spectroscopy.
    Fantini, S., & Sassaroli, A. (2020).
    Frontiers in Neuroscience, 14, 300.Amplitude and phase, and why phase carries depth.

The modality table, sourced

The EEG, MEG, fMRI, fNIRS and FOS figures on the home and technology pages are typical published ranges. Each row's source is below.

Sources for each row of the modality comparison
ModalityFigures we quoteSource
EEG~1 ms temporal · ~1–5 cm spatial · portableBurle et al. (2015), Int. J. Psychophysiology 97(3), 210–220, doi:10.1016/j.ijpsycho.2015.05.004; Michel & Brunet (2019), Frontiers in Neurology 10, 325.
MEG~1 ms · ~2–5 mm · shielded roomBaillet (2017). Magnetoencephalography for brain electrophysiology and imaging. Nature Neuroscience 20(3), 327–339.
fMRI~3–6 s · ~1–3 mm · whole brain · fixed scannerLogothetis (2008). What we can do and what we cannot do with fMRI. Nature 453, 869–878.
fNIRS~4–6 s · ~5–15 mm · ~1–3 cm depth · portableScholkmann et al. (2014), NeuroImage 85, 6–27; Pinti et al. (2020), Ann. N.Y. Acad. Sci. 1464(1), 5–29.
FOS5–10 ms · sub-centimeter · ~1–3 cm depth · portableGratton & Fabiani (2010), Front. Hum. Neurosci. 4, 52; Gratton et al. (1997), NeuroImage 6(3), 168–180; Parks et al. (2012), NeuroImage 59(3), 2504–2510; Parks et al. (2015), Neuropsychologia 78, 153–158.

CLAIMS REGISTER

What we say, and what it rests on.

Every substantive claim on this site, where it appears, and its basis.published means a peer-reviewed source, cited above or in the basis column.ours means our own data, estimate or design specification.statement means a position we take as a company.

ClaimWhereBasisType
Fast optical signal was first demonstrated non-invasively in humans in 1995.Home, blogGratton et al. 1995 [1]published
Neurons change shape when they fire, which changes how tissue scatters light.Home, technologyCohen 1973 [7]; Stepnoski et al. 1991 [8]; Gratton & Fabiani 2001 [3]published
Fast signal has been recorded from motor cortex.HomeWolf et al. 2002 [4]published
FOS penetration is up to about 3 cm.Home, technologyGratton & Fabiani 2010 [6]published
FOS localizes to the sub-centimeter level.Home, technologyGratton & Fabiani 2010 [6]published
EEG, MEG, fMRI and fNIRS ranges in the modality table.Home, technologySources in the table abovepublished
FOS temporal resolution of 5–10 ms.Home, technologyParks et al. (2012), NeuroImage 59(3), 2504–2510; Parks et al. (2015), Neuropsychologia 78, 153–158.published
The optical response to a motor command appears about 96 ms before the button press.HomeDeSoto et al. (2001), J. Cogn. Neurosci. 13(4), 523–536.published
Published studies: EEG 542,256 · fMRI 176,076 · fNIRS 19,593 · FOS 136.Home, blogOur count of OpenAlex-indexed works, 2026.ours
More photons enter the skull on a sunny day than the instrument emits.Home, technology, participateOur estimate, from near-infrared solar irradiance and the instrument's emission.ours
Our CTO built the only commercial instrument sold for FOS measurement.Home, teamISS markets the Imagent for EROS measurement. No other maker on the fNIRS Society's instrument list advertises a fast-signal mode (our review of manufacturers' sites, October 2026).statement
The first device designed from the ground up for FOS.HomeOur reading of the published instrumentation.statement
FOS is the only non-invasive method that delivers on all four elements: speed, precision, coverage, and portability.HomeFollows from the modality table, on the figures cited.statement
Our instruments are investigational and not cleared or approved by any regulator.TermsRegulatory status as of the effective date.statement

If you've read this far, we'd like to talk.

Optics, electrical, firmware, signal processing, computational neuroscience.

See open roles